Alluris - Calibration certificates

CAL-210
Calibration - DKD-R 3-3 (B)

€235.00

Verification and calibration of force measurement systems (force gauge, load cell with amplifier and indicator) traceable to PTB/DKD/ILAC standards. The directive DKD-R 3-3 describes calibration procedures for force measuring systems. The reduced scope according procedure "B" calibrates the object in one position with 2 measuring rows with increasing and decreasing force levels at 5 points. This procedure can apply if "a-priori" knowledge is available to calculate the uncertainty accordingly. The calibration for tensile and compression force (pull and push direction) is performed on an automated calibration stand with direct staggered mass application for forces up to 1000N. The lowest resolution is 0,2N for force gauges with 2N measuring range. Force gauges with nominal measuring range higher 1kN are calibrated on a stand with transfer standards up to 250 kN. Please consult the below table in order to check which measuring ranges of the calibration stands are covered by the accreditation in relation to the nominal force range of your gauge.

  • Traceability according to requirements of ISO/TS 16949 or ISO 9001:2015
  • Calibration maschines and accredited according ISO 17025 with scope from 2N to 250kN.
  • Highest precision and low uncertainty (CMC better 0,02%)
Tension & Compression
Compression
Tension
Alluris
CMC (accredited)

Models/Price

Select Part no. Direction Range F(nom) CMC (accredited) Availability Price €
CAL-210A5B Calibration Certificate acc. DKD-R 3-3 (B) Zug/Druck 1-5 N -   335,00
CAL-210A5D Calibration Certificate acc. DKD-R 3-3 (B) Druck 1-5 N -   235,00
CAL-210A5Z Calibration Certificate acc. DKD-R 3-3 (B) Zug 1-5 N -   235,00
CAL-210B5B Calibration Certificate acc. DKD-R 3-3 (B) Zug/Druck 10-50 N 0,02 %   335,00
CAL-210B5D Calibration Certificate acc. DKD-R 3-3 (B) Druck 10-50 N 0,02 %   235,00
CAL-210B5Z Calibration Certificate acc. DKD-R 3-3 (B) Zug 10-50 N 0,02 %   235,00
CAL-210K1B Calibration Certificate acc. DKD-R 3-3 (B) Zug/Druck 60-1000 N 0,02 %   335,00
CAL-210K1D Calibration Certificate acc. DKD-R 3-3 (B) Druck 60-1000 N 0,02 %   235,00
CAL-210K1Z Calibration Certificate acc. DKD-R 3-3 (B) Zug 60-1000 N 0,02 %   235,00
CAL-210K5B Calibration Certificate acc. DKD-R 3-3 (B) Zug/Druck 25-5000 N 0,1 %   335,00
CAL-210K5D Calibration Certificate acc. DKD-R 3-3 (B) Druck 25-5000 N 0,1 %   235,00
CAL-210K5Z Calibration Certificate acc. DKD-R 3-3 (B) Zug 25-5000 N 0,1 %   235,00
CAL-210M2B Calibration Certificate acc. DKD-R 3-3 (B) Zug/Druck 2500-25000 N 0,1 %   335,00
CAL-210M2D Calibration Certificate acc. DKD-R 3-3 (B) Druck 2500-25000 N 0,1 %   235,00
CAL-210M2Z Calibration Certificate acc. DKD-R 3-3 (B) Zug 2500-25000 N 0,1 %   235,00
CAL-210T2B Calibration Certificate acc. DKD-R 3-3 (B) Zug/Druck 15000-250000 N 0,1 %   335,00
CAL-210T2D Calibration Certificate acc. DKD-R 3-3 (B) Druck 15000-250000 N 0,1 %   235,00
CAL-210T2Z Calibration Certificate acc. DKD-R 3-3 (B) Zug 15000-250000 N 0,1 %   235,00

Models and specifications

CAL-210K1B

Calibration - DKD-R 3-3 (B)
Tension & Compression
60.00
1000.00
N
0.02
%

CAL-210K1D

Calibration - DKD-R 3-3 (B)
Compression
60.00
1000.00
N
0.02
%

CAL-210K1Z

Calibration - DKD-R 3-3 (B)
Tension
60.00
1000.00
N
0.02
%

CAL-210K5B

Calibration - DKD-R 3-3 (B)
Tension & Compression
25.00
5000.00
N
0.10
%

CAL-210K5D

Calibration - DKD-R 3-3 (B)
Compression
25.00
5000.00
N
0.10
%

CAL-210K5Z

Calibration - DKD-R 3-3 (B)
Tension
25.00
5000.00
N
0.10
%

CAL-210M2B

Calibration - DKD-R 3-3 (B)
Tension & Compression
2500.00
25000.00
N
0.10
%

CAL-210M2D

Calibration - DKD-R 3-3 (B)
Compression
2500.00
25000.00
N
0.10
%

CAL-210M2Z

Calibration - DKD-R 3-3 (B)
Tension
2500.00
25000.00
N
0.10
%

CAL-210T2B

Calibration - DKD-R 3-3 (B)
Tension & Compression
15000.00
250000.00
N
0.10
%

CAL-210A5B

Calibration - DKD-R 3-3 (B)
Tension & Compression
1.00
5.00
N

CAL-210T2D

Calibration - DKD-R 3-3 (B)
Compression
15000.00
250000.00
N
0.10
%

CAL-210A5D

Calibration - DKD-R 3-3 (B)
Compression
1.00
5.00
N

CAL-210T2Z

Calibration - DKD-R 3-3 (B)
Tension
15000.00
250000.00
N
0.10
%

CAL-210A5Z

Calibration - DKD-R 3-3 (B)
Tension
1.00
5.00
N

CAL-210B5B

Calibration - DKD-R 3-3 (B)
Tension & Compression
10.00
50.00
N
0.02
%

CAL-210B5D

Calibration - DKD-R 3-3 (B)
Compression
10.00
50.00
N
0.02
%

CAL-210B5Z

Calibration - DKD-R 3-3 (B)
Tension
10.00
50.00
N
0.02
%
Talk to your Alluris representative for your country about solutions, pricing and support
 

Got a question about this solution?
Get in touch and speak to one of our Technical Sales Engineers now...

Speak to an expert