Alluris - Calibration certificates

CAL-200
Force sensor/loadcell (DKD-R 3-3 (A))

€395.00

Verification and calibration of force measurement systems (force gauge, load cell with amplifier and indicator) traceable to PTB/DKD/ILAC standards. The directive DKD-R 3-3 describes calibration procedures for force measuring systems.

The full scope according procedure A covers the accuracy, repeatability and hystereses by calibrating the object in 3 differents positions, each with 5 increasing and decreasing force levels.

This procedure is recommended if uncomplete specifications from the manufactureres data sheet, the type approval or previous calibration according DIN ISO 376 or DKD-R 3-3 are available only.

The calibration for tensile and compression force (pull and push direction) is performed on an automated calibration stand with direct staggered mass application for forces up to 1000N.

The lowest resolution is 0,2N for force gauges with 2N measuring range. Force gauges with nominal measuring range higher 1kN are calibrated on a stand with transfer standards up to 250 kN.

Please consult the below table in order to check which measuring ranges of the calibration stands are covered by the accreditation in relation to the nominal force range of your gauge.

  • Traceability according to requirements of IATF 16949:2016 or ISO 9001:9015
  • Calibration machines with ISO 17025 accredited measuring range from 2 N to 250 kN
  • Highest precision, low uncertainty (CMC better 0,02%)
Tension & Compression
Compression
Tension
Alluris
CMC (accredited)

Models and specifications

CAL-200K5D

Calibration - DKD-R 3-3 (A)
Compression
25.00
5000.00
N
0.10
%

CAL-200K5Z

Calibration - DKD-R 3-3 (A)
Tension
25.00
5000.00
N
0.10
%

CAL-200M2B

Calibration - DKD-R 3-3 (A)
Tension & Compression
2500.00
25000.00
N
0.10
%

CAL-200M2D

Calibration - DKD-R 3-3 (A)
Compression
2500.00
25000.00
N
0.10
%

CAL-200M2Z

Calibration - DKD-R 3-3 (A)
Tension
2500.00
25000.00
N
0.10
%

CAL-200T2B

Calibration - DKD-R 3-3 (A)
Tension & Compression
15000.00
250000.00
N
0.10
%

CAL-200T2D

Calibration - DKD-R 3-3 (A)
Compression
15000.00
250000.00
N
0.10
%

CAL-200T2Z

Calibration - DKD-R 3-3 (A)
Tension
15000.00
250000.00
N
0.10
%

CAL-200A5Z

Calibration - DKD-R 3-3 (A)
Tension
1.00
5.00
N

CAL-200B5B

Calibration - DKD-R 3-3 (A)
Tension & Compression
10.00
50.00
N
0.02
%

CAL-200B5D

Calibration - DKD-R 3-3 (A)
Compression
10.00
50.00
N
0.02
%

CAL-200B5Z

Calibration - DKD-R 3-3 (A)
Tension
10.00
50.00
N
0.02
%

CAL-200K1B

Calibration - DKD-R 3-3 (A)
Tension & Compression
60.00
1000.00
N
0.02
%

CAL-200K1D

Calibration - DKD-R 3-3 (A)
Compression
60.00
1000.00
N
0.02
%

CAL-200K1Z

Calibration - DKD-R 3-3 (A)
Tension
60.00
1000.00
N
0.02
%

CAL-200K5B

Calibration - DKD-R 3-3 (A)
Tension & Compression
25.00
5000.00
N
0.10
%

CAL-200A5B

Calibration - DKD-R 3-3 (A)
Tension & Compression
1.00
5.00
N

CAL-200A5D

Calibration - DKD-R 3-3 (A)
Compression
1.00
5.00
N
Talk to your Alluris representative for your country about solutions, pricing and support
 

Got a question about this solution?
Get in touch and speak to one of our Technical Sales Engineers now...

Speak to an expert